Gradation bands · Table 320-3
INVIAS 2013, Table 320-3. Granular subbase gradation bands, % passing| Band | 2" (50.0 mm) | 1½" (37.5 mm) | 1" (25.0 mm) | 1/2" (12.5 mm) | 3/8" (9.5 mm) | No. 4 (4.75 mm) | No. 10 (2.00 mm) | No. 40 (0.425 mm) | No. 200 (0.075 mm) |
|---|
| SBG-50 | 100 | 70-95 | 60-90 | 45-75 | 40-70 | 25-55 | 15-40 | 6-25 | 2-15 |
|---|
| SBG-38 | - | 100 | 75-95 | 55-85 | 45-75 | 30-60 | 20-45 | 8-30 | 2-15 |
|---|
Production tolerances on the job mix formula (±): 0 % on the 2" sieve; 7 % from 1½" to 3/8"; 6 % from No. 4 to No. 40; 3 % on No. 200.
Source: Instituto Nacional de Vías (INVIAS). Especificaciones Generales de Construcción de Carreteras, 2013. Capítulo 3, Artículo 320 (Sub-base granular), Tablas 320-2 y 320-3. Check the edition in force and the one your contract requires; INVIAS published a 2022 edition.
Questions on INVIAS granular subbase
What minimum CBR does INVIAS require for granular subbase?
30 % for classes C and B and 40 % for class A, with test INV E-148 (INVIAS 2013, Table 320-2). These are the requirements of the standard. Compliance of each material and each shipment is proven with its tests; ask for them when you request a quote.
What is the maximum plasticity index of the subbase?
6 % in all three classes, C, B and A, with tests INV E-125 and E-126; the maximum liquid limit is 25 % (INVIAS 2013, Table 320-2). These are the requirements of the standard. Compliance of each material and each shipment is proven with its tests; ask for them when you request a quote.
What is the difference between SBG-50 and SBG-38?
SBG-50 passes 100 % through the 2" (50.0 mm) sieve and 70-95 % through the 1½" (37.5 mm); SBG-38 passes 100 % through the 1½" and 75-95 % through the 1" (25.0 mm). On the No. 200 (0.075 mm) sieve both require 2-15 % (INVIAS 2013, Table 320-3). These are the requirements of the standard. Compliance of each material and each shipment is proven with its tests; ask for them when you request a quote.
What Los Angeles and Micro-Deval values does INVIAS allow for granular subbase?
Los Angeles abrasion (Grading A, 500 revolutions) maximum 50 % in all three classes (INV E-218). Micro-Deval maximum 35 % for class B and 30 % for class A (INV E-238); the table sets no value for class C (INVIAS 2013, Table 320-2). These are the requirements of the standard. Compliance of each material and each shipment is proven with its tests; ask for them when you request a quote.
What sand equivalent and soundness does granular subbase require?
Minimum sand equivalent 25 % (INV E-133) and maximum sulfate soundness loss of 12 % with sodium sulfate and 18 % with magnesium sulfate (INV E-220), in all three classes (INVIAS 2013, Table 320-2). These are the requirements of the standard. Compliance of each material and each shipment is proven with its tests; ask for them when you request a quote.
What gradation tolerances does granular subbase allow?
Production tolerances on the job mix formula (±): 0 % on the 2" sieve; 7 % from 1½" to 3/8"; 6 % from No. 4 to No. 40; 3 % on No. 200. (INVIAS 2013, Table 320-3). These are the requirements of the standard. Compliance of each material and each shipment is proven with its tests; ask for them when you request a quote.