Meteoro

STANDARD GUIDE · INVIAS 2013

INVIAS granular subbase: requirements and SBG-50 and SBG-38 gradations

INVIAS 2013, Article 320, sets the aggregate requirements for granular subbase in three classes, C, B and A, and two gradation bands, SBG-50 and SBG-38. The minimum CBR is 30 % for classes C and B and 40 % for class A, and the maximum plasticity index is 6 % in all three.

These are the requirements of the standard. Compliance of each material and each shipment is proven with its tests; ask for them when you request a quote.

Aggregate requirements · Table 320-2

INVIAS 2013, Table 320-2. Aggregate requirements for granular subbases
PropertyTest standardClass CClass BClass A
Los Angeles abrasion (Grading A), 500 revolutions, maximum (%)INV E-218505050
Micro-Deval abrasion degradation, maximum (%)INV E-238-3530
Sulfate soundness loss, maximum (%), sodium sulfateINV E-220121212
Sulfate soundness loss, maximum (%), magnesium sulfateINV E-220181818
Liquid limit, maximum (%)INV E-125252525
Plasticity index, maximum (%)INV E-125 and E-126666
Sand equivalent, minimum (%)INV E-133252525
Clay lumps and friable particles, maximum (%)INV E-211222
CBR (%), minimumINV E-148303040

Source: Instituto Nacional de Vías (INVIAS). Especificaciones Generales de Construcción de Carreteras, 2013. Capítulo 3, Artículo 320 (Sub-base granular), Tablas 320-2 y 320-3. Check the edition in force and the one your contract requires; INVIAS published a 2022 edition.

Gradation bands · Table 320-3

INVIAS 2013, Table 320-3. Granular subbase gradation bands, % passing
Band2" (50.0 mm)1½" (37.5 mm)1" (25.0 mm)1/2" (12.5 mm)3/8" (9.5 mm)No. 4 (4.75 mm)No. 10 (2.00 mm)No. 40 (0.425 mm)No. 200 (0.075 mm)
SBG-5010070-9560-9045-7540-7025-5515-406-252-15
SBG-38-10075-9555-8545-7530-6020-458-302-15

Production tolerances on the job mix formula (±): 0 % on the 2" sieve; 7 % from 1½" to 3/8"; 6 % from No. 4 to No. 40; 3 % on No. 200.

Source: Instituto Nacional de Vías (INVIAS). Especificaciones Generales de Construcción de Carreteras, 2013. Capítulo 3, Artículo 320 (Sub-base granular), Tablas 320-2 y 320-3. Check the edition in force and the one your contract requires; INVIAS published a 2022 edition.

Questions on INVIAS granular subbase

What minimum CBR does INVIAS require for granular subbase?

30 % for classes C and B and 40 % for class A, with test INV E-148 (INVIAS 2013, Table 320-2). These are the requirements of the standard. Compliance of each material and each shipment is proven with its tests; ask for them when you request a quote.

What is the maximum plasticity index of the subbase?

6 % in all three classes, C, B and A, with tests INV E-125 and E-126; the maximum liquid limit is 25 % (INVIAS 2013, Table 320-2). These are the requirements of the standard. Compliance of each material and each shipment is proven with its tests; ask for them when you request a quote.

What is the difference between SBG-50 and SBG-38?

SBG-50 passes 100 % through the 2" (50.0 mm) sieve and 70-95 % through the 1½" (37.5 mm); SBG-38 passes 100 % through the 1½" and 75-95 % through the 1" (25.0 mm). On the No. 200 (0.075 mm) sieve both require 2-15 % (INVIAS 2013, Table 320-3). These are the requirements of the standard. Compliance of each material and each shipment is proven with its tests; ask for them when you request a quote.

What Los Angeles and Micro-Deval values does INVIAS allow for granular subbase?

Los Angeles abrasion (Grading A, 500 revolutions) maximum 50 % in all three classes (INV E-218). Micro-Deval maximum 35 % for class B and 30 % for class A (INV E-238); the table sets no value for class C (INVIAS 2013, Table 320-2). These are the requirements of the standard. Compliance of each material and each shipment is proven with its tests; ask for them when you request a quote.

What sand equivalent and soundness does granular subbase require?

Minimum sand equivalent 25 % (INV E-133) and maximum sulfate soundness loss of 12 % with sodium sulfate and 18 % with magnesium sulfate (INV E-220), in all three classes (INVIAS 2013, Table 320-2). These are the requirements of the standard. Compliance of each material and each shipment is proven with its tests; ask for them when you request a quote.

What gradation tolerances does granular subbase allow?

Production tolerances on the job mix formula (±): 0 % on the 2" sieve; 7 % from 1½" to 3/8"; 6 % from No. 4 to No. 40; 3 % on No. 200. (INVIAS 2013, Table 320-3). These are the requirements of the standard. Compliance of each material and each shipment is proven with its tests; ask for them when you request a quote.

Subbase data sheets

Quote on WhatsApp → · Catalog by specification →